Plaintile

Britmet Lightweight Roofing’s lightweight plaintile system is the world’s only true broken bond plaintile lightweight roofing system.

Free Estimate Buy Now

Features & Benefits

  • Manufactured in Britain
  • Ideal for vertical cladding applications
  • Minimum pitch 15 degrees
  • Only 5 tiles per sqm
  • 50-year warranty
  • AA fire rating equal to traditional roof tiles

Plaintile Overview

Britmet Lightweight Roofing’s Plaintile system is the world’s only true broken bond Plaintile lightweight roofing system. The only tile to give a true characteristic of a traditional Plaintile, providing an attractive and economic finish for all roof styles, even for vertical cladding.

Britmet’s Plaintile system can be fixed down to a 15° roof pitch and is highly effective at reducing installation time as it’s 7 traditional tiles wide and on tile high. This means that only 5 Plaintile panels are required per sqm. This is a huge difference in comparison to traditional plain tiles which required 60 tiles per sqm.

Available in 6 colours and weighing 1/7th the weight of traditional tiles, the Britmet Plaintile is manufactured in Britain from the highest-grade Aluzinc Steel and coated with the most superior external coating on the market for effortless weather protection.

Titanium Grey

Titanium Grey

Bramble Brown

Bramble Brown

Rustic Brown

Rustic Brown

Rustic Terracotta

Rustic Terracotta

Moss Green

Moss Green
Currently Unavailable

Tartan Green

Tartan Green

Plaintile Brochure

Plaintile Photo Gallery

Plaintile Product Range

Plaintile Case Studies

Plaintile Technical Spec

Minimum pitch: 15°
Maximum pitch: 90°
Overall width: 1320mm
Cover width: 1260mm
Side lap: 60mm
Step: 20mm
Batten gauge: 160mm
Roof cover per panel: 0.2m2
Slates per sqm: 5
Steel base: 0.45mm
Weight as laid per m2: 8kg & 12kg
Base coat: Acrylic resin
Top coat: Stone granules with clear acrylic overglaze
Colours available: Titanium Grey, Bramble Brown, Tartan Green and Rustic Terracotta
Chemical resistance: Non-toxic fungicide incorporated
Biological resistance: Unaffected by normal pollution
Fire resistance: AA classification equal to traditional roof tiles and slates
Fixings: The contractor shall utilise the roofing manufacturers recommended fixings and sealant
Ventilation: Roof ventilation should meet. The recommendations of Building Regulations 1991 (amended 1992 and 1994). Approved document F2 1995 ‘Condensation in roofs’, BS5250: 1989 ‘control of condensation’.

Plaintile General Specification

Plain Tile panels roof pitches from 15° to 90°

Plain Tile lightweight roofing tiles, to be supplied by Britmet.
Each tile must be secured using 4 coloured 2.6mm x 50mm galvanised fixing nails, driven through the downturned nose of the tile into the face of the battens.

Battens
Treated tiling battens of approved quality (E.g., tanalised), of suitable section, should be laid at 160mm centres, (for 0.45mm thick) except the eaves batten (see eaves section), and secured to the rafters using galvanised nails. Joints in the battens should be staggered and meet halfway across the top of the rafters, as standard code of practice.
Please note: It is the responsibility of the installer to ensure correct batten usage

Underlay
Approved reinforced felt, BS747 (Type 1F) must be laid over rafters, lapped and secured to the rafters with galvanised clout nails and carried well into gutters. All to comply with current regulations.

Angle Ridge Flashing
Two tile battens should be fitted side by side on both sides of the ridge using galvanised nails. An additional 50mm x 50mm batten is to be secured on top of the rearmost of the two tile battens in a position to suit the fitting of the Plaintile angle ridge.
If necessary, the top course of tiles can be cut and bent using a guillotine and bender (available to hire from Britmet). The rear edge of the tile is to be turned up to form a 25mm - 38mm upstand against the top tile batten. Each tile must be secured using 4 nails driven through the downturn as previously described.
The angle ridge flashing is to be fitted over the top batten and nailed through the downturn of the ridge into the tile upstand and face of the batten, using 5 nails on each side.

Angle Ridge (ventilated) Roof Pitches From 10° To 35°
Felt underlay must be cut back allowing a continuous 12.5mm air gap on either side of the centre line of the ridge.
If necessary, the top course of tiles can be cut and bent using a guillotine and bender (available to hire from Britmet). Each tile can then be secured using 4 fixing nails driven through the downturn nose of the tile and into the battens. A batten, not exceeding 50mm x 50mm should be fitted on the universal vent piece (supplied by Britmet) and secured through the tile into the battens on the underside, using 75mm galvanised nails.
The ridge flashing should be fitted over the batten and nailed through the downturn into the face of the batten using 5 nails on each side.

Angle Hip Flashing
A 38mm x 38mm hip batten is to be nailed to the tile battens on each side of the hip rafter using galvanised nails.
Tiles should be cut and bent to form a 25mm - 35mm upstand against the hip battens, using a guillotine and bender (available to hire from Britmet).
The hip flashing is to be fitted over the battens and nailed through the downturn, into the face of the battens using 5 nails on each side.

Eaves
The bottom course of tiles is to be secured using 4 coloured 2.6mm x 50mm galvanised fixing nails. These must be driven vertically through the tile, as near to the high point of the tile profile as possible and into the fascia board or through the eaves batten placed approx. 20mm behind the fascia board if the Plaintile eaves ventilation system is used. These nail heads will then be sealed using the Plaintile touch-up kit.
If using the top of the fascia board or eaves vent, this must be in line with the top of the battens.
Then, fit Lay Board or Tilting Fillet at the eaves if appropriate, to ensure any moisture on the underlay drains into gutter.

Eaves Ventilation
Roof pitch above 15°
The top of the fascia board should be fixed 23mm below the top face of the eaves batten allowing for the Plaintile 10mm eaves vent system.
Roof pitch below 15°
The top of the fascia board should be fixed 25mm below the top face of the eaves batten allowing for the Plaintile 25mm eaves vent system. Note: Where the insulation follows the roof slope, the Plaintile ventilation tray should be installed between the rafters.

Valley
The valley should be formed from lead, moulded glass fibre or similar approved lining, supported on valley boards.
Tile battens should project over the valley to provide fixing for the tiles.
Plaintile panels should be measured, cut and bent using a guillotine and bender (available to hire from Britmet), allowing sufficient downturn into the valley.

Barge Board Cover
The timber barge board should project 25mm above the top of the tile battens. A 50mm x 50mm timber batten to run parallel to the fascia board. Plaintile panels should be cut and bent up against the timber barge batten.
The Plaintile scribed barge board cover is to be secured using 5 fixing nails driven through the downturned edge into the barge board and 5 nails to be driven vertically into the barge batten (the heads of the vertically fixed nails to be sealed, using the Plaintile touch-up kit).

Sidewall Flashing
Plaintile scribed sidewall flashing should be secured using fixing nails, one driven vertically into each batten (these nail heads need to be covered, using the Plaintile finishing kit).
Plaintile cover flashing should then be dressed over the vertical section of the side wall flashing and dressed into the brickwork.

Plaintile Inline and Soil Vent
To provide additional ventilation, the Plaintile inline tile vents are available, providing an airflow of 7,500mm2.
The tile underlay must be cut to allow the spigot of the tile vent to pass through. The Plaintile panel vent is installed to provide full weather security. The tile vent is secured by overlapping a Plaintile panel on either side and nailing through the nose of the tile, as previously described. Nails must not penetrate the vent tile.
The Plaintile inline vent tile can also be used as a weather protected exit point for soil pipes or extractor fan ducts by means of a flexi-hose and pipe adapter that connects the vent to 100mm stacts or duct work.

Plaintile Gas Flue Ridge Terminal
Available to suit angle ridge. Type (R) adapter and extension piece supplied by others.
Please note: This information is to be used as a guide only. It assumes that the structure of the existing building is in accordance with the building practice.
At your request a custom specification can be written for your individual project. Please contact our technical department for assistance.

Plaintile NBS Spec

Plaintile Installer Guide

You can download our installer's guide here (PDF)

Plaintile Videos

Fitting of Britmet Tileform Junction flashing to private house
Play
Fitting of Britmet Tileform Junction flashing to private house
Fitting of Britmet Tileform PIR insulation broads and with taped joints
Play
Fitting of Britmet Tileform PIR insulation broads and with taped joints
Fitting of the Britmet Tileform breather membrane over counter battens
Play
Fitting of the Britmet Tileform breather membrane over counter battens
Fitting of the Britmet Tileform vertical end closer flashing
Play
Fitting of the Britmet Tileform vertical end closer flashing
Fitting of the Britmet tileform vertical window head jamb flashing
Play
Fitting of the Britmet tileform vertical window head jamb flashing
Fitting of the vertical Britmet Tileform Plaintile battens
Play
Fitting of the vertical Britmet Tileform Plaintile battens
General fitting of the Britmet Tileform Vertical Plaintile system
Play
General fitting of the Britmet Tileform Vertical Plaintile system
New counter battens to increase vertical void depth to accept new BTL PIR insulation of 0.13 u value
Play
New counter battens to increase vertical void depth to accept new BTL PIR insulation of 0.13 u value
Removal of existing Vertical Plaintile Cladding
Play
Removal of existing Vertical Plaintile Cladding
Removal of the existing Plaintile vertical battens
Play
Removal of the existing Plaintile vertical battens
Removal of the existing plaintile vertical broads
Play
Removal of the existing plaintile vertical broads
How to tile a roof with lightweight metal roof tiles: Hip
Play
How to tile a roof with lightweight metal roof tiles: Hip
How to tile a roof with lightweight metal roof tiles: Barge Verge
Play
How to tile a roof with lightweight metal roof tiles: Barge Verge
How to tile a roof with lightweight metal roof tiles: Hip End Cap
Play
How to tile a roof with lightweight metal roof tiles: Hip End Cap
How to tile a roof with lightweight metal roof tiles: Ridge Hip Junction
Play
How to tile a roof with lightweight metal roof tiles: Ridge Hip Junction
How to tile a roof with lightweight metal roof tiles: Rooflight Window
Play
How to tile a roof with lightweight metal roof tiles: Rooflight Window
How to tile a roof with lightweight metal roof tiles: Slate 2000
Play
How to tile a roof with lightweight metal roof tiles: Slate 2000
How to tile a roof with lightweight metal roof tiles: Valley
Play
How to tile a roof with lightweight metal roof tiles: Valley
How to tile a roof with lightweight metal roof tiles: Ridge
Play
How to tile a roof with lightweight metal roof tiles: Ridge
How to tile a roof with lightweight metal roof tiles: Ridge End Cap
Play
How to tile a roof with lightweight metal roof tiles: Ridge End Cap
How to tile a roof with lightweight metal roof tiles: Tile Vent
Play
How to tile a roof with lightweight metal roof tiles: Tile Vent
Eave Tray and Eave Vent Strip
Play
Eave Tray and Eave Vent Strip
How to install a rooflight window
Play
How to install a rooflight window
How to set out battens for lightweight metal roof tiles
Play
How to set out battens for lightweight metal roof tiles
Laying Breather Membrane
Play
Laying Breather Membrane

Plaintile Technical Drawings

RefDescriptionFiles

BLR-CAD-PLAINTILE-0005PlaintileDWG | JPG
SK-054Plaintile TilePDF