| Min. pitch: |
 |
5° |
|
|
| Max. pitch: |
 |
90° |
|
|
| Overall width: |
 |
840mm |
|
|
| Cover width: |
 |
760mm |
|
|
| Side lap: |
 |
80mm |
|
|
| Step: |
 |
20mm |
|
|
| Purlin Centres: |
 |
1800 (0.9mm only) |
|
|
| Individual tile module: |
 |
300mm |
|
|
| Maximum sheet length: |
 |
6m (over 6m for special orders) |
|
|
| Steel base: |
 |
0.9mm |
|
|
| Weight as laid per m2: |
 |
11kg |
|
|
| Base coat: |
 |
Acrylic resin |
|
|
| Top coat: |
 |
Pigmented mineral filled acrylic |
|
|
| Colours available: |
 |
Charcoal, Terracotta, Mid Grey, Tudor, Brown, Antique Red, Sage Green |
|
|
| Chemical resistance: |
 |
Unaffected by normal pollution |
|
|
| Biological resistance: |
 |
Non toxic fungicide incorporated |
|
|
| Fire resistance: |
 |
AA classification equal to traditional roof tiles and slates |
|
|
| Fixings: |
 |
The contractor shall utilise the roofing manufacturers recommended fixings and sealant |
|
|
| Ventilation: |
 |
Roof ventilation should meet recommendations of Building Regulations 1991 (amended ‘92, ‘94). Approved Document F2 1995 ‘Condensation in roofs', BS 5250# 1989' Control of condensation' |
|
|